Stationeers mods
Stationeers ic code mods
Everything filed under ic code by its own author, ordered by how much it is used.
1,093 ic code mods, most downloaded first · newest update 24 Sep 2026
AllIC Code1.1kWorld Save201World Settings112StationeersLaunchPad101World65Start Conditions49Starting Conditions33Crafting9QoL9Scenario6Utility6Translation5
1.1k ic code mods
- Ingot circulatorby CowsAreEvilThis is a little script to handle transfer of ingots between your production machines. I got sick of transferring ingots between production units so I made this. It makes for a nice tidy production area with a single input for the system and a single output stacker. Connecting the chutes is a bit...568 downloadsupdated 6 y ago
- Scripted Screens - Energy Grid Dashboardby 3xpThis script has been replaced by a new version. The new version includes solar sun tracking, better autologic for the generators, easier setup and better stability. You can find it here: PIAC - Power Info and Control 🌬️ Real-Time Power Tracking 🌞 Monitor your energy generating devices with ease!...564 downloadsupdated 8 mo ago
- Advanced Furnace - 5 of 5 - Alloys CPUby LAsger562 downloadsupdated 6 y ago
- Advanced Furnace Interface (IC2)by Nominal_This Advanced Furnace script manages the interface, stores alloy recipes, requests ore, and makes it all work!​560 downloadsupdated 4 y ago
- Combustion Centrifuge Adaptive Quadratic Controlby RyexandraCombustion Centrifuge automation One chip installed in the machine, no outside IC Housing or sensor needed. Optional "Ejection Override" lever on d0. Adapts perfectly to *any* fuel ratio using Oxygen or Nitrous. Even a mix of the two. Works by calculating the final combustion temperature of the f...546 downloadsupdated 22 mo ago
- [Deprecated] Universal Combustion Centrifugeby MerGattoPlease use the new version, which also supports Combustion Deep Miners and is generally more stable:545 downloadsupdated 2 y ago
- Advanced Furnace - 1 of 5 - Mode Select CPUby LAsgerThis script is part of a series of 5 scripts intended for CPU's to run an automated advanced furnace. Besides the 5 CPU, this setup uses 2 dials (one for setting which type of ingot you'd like to create (Standard Metal, Alloy or Super Alloy) and one for selecting specifically which type of ingot...543 downloadsupdated 7 y ago
- Advanced Furnace - 3 of 5 - Superalloys CPUby LAsgerThis script is part of a series of 5 scripts intended for CPU's to run an automated advanced furnace. Besides the 5 CPU, this setup uses 2 dials (one for setting which type of ingot you'd like to create (Standard Metal, Alloy or Super Alloy) and one for selecting specifically which type of ingot...542 downloadsupdated 7 y ago
- Simple Power Displayby Lu5ckIntroduction I needed to get the average ratio of my batteries bank so my IC10 controlling my Stirling's input will turn on and off on demand. Since I am already getting codes going, might as well make a detail stats display as well. The part related to my Stirling's is not included, this is just...542 downloadsupdated 2 y ago
- Crafting Buddy - One Display to control them ALL!by 3xpFeatures 100% automation of your crafting operation! Select a station, the amount and start crafting. Able to control all major crafting stations (auto versions)(packaging station and automated oven excluded (will come with another script)) Batch crafting operation! Select which recipes and amoun...542 downloadsupdated 7 mo ago
- [F&S] Full Auto Airlock (Light Version)by 123Description Fully automated airlock, just build and forget. Retains the existing atmosphere in the pipe when the airlock closes, and release it when the same side is going to open again. Does not check the pressure behind the doors, if you need it, read the Related section. Requirements 1 Gas Sen...539 downloadsupdated 4 y ago
- Automatic Doorby HoschiTvHello dear comunity, i know it sounds silly. But have you ever dreamed from Automatic Doors like in Star Trek. :P Now your wet dreams come true. Connect 2 Movesensors screw ( D0 & D1) 1. in the Floor at one side of the door, 2. in the Floor at the other side. and a door to screw (D2). Never again...538 downloadsupdated 7 y ago
- Advanced Furnace Calculator (IC1)by Nominal_Calculates how much of each gas to inject based on hot, cold, and furnace atmospherics data for a given alloy.​536 downloadsupdated 4 y ago
- Power managerby CowsAreEvilI couldn't find a power management script that did everything that I wanted, so I wrote my own. Solar alignment of course. It wouldn't be much a power management script if it didn't. Optional backup generator activation for when the power is low. Optional display for current power levels. It will...534 downloadsupdated 6 y ago
- Station Battery Display (2023)by KassfaruPlace the IC in the Data Line with the Batterys. Dosen`t matter how much Station Batterys and which size. Install 3 Led Consoles. For the Power In Display, name it to "DispChaIn". For the Charge State in Percent name the Display to "DispPowPer" For the Power out Display name it to "DispChaOut" ​...534 downloadsupdated 3 y ago
- Advanced Furnace - 4 of 5 - Normal Metals CPUby LAsgerThis script is part of a series of 5 scripts intended for CPU's to run an automated advanced furnace. Besides the 5 CPU, this setup uses 2 dials (one for setting which type of ingot you'd like to create (Standard Metal, Alloy or Super Alloy) and one for selecting specifically which type of ingot...532 downloadsupdated 7 y ago
- Advanced Furnace - 2 of 5 - Settings Display CPUby LAsgerThis script is part of a series of 5 scripts intended for CPU's to run an automated advanced furnace. Besides the 5 CPU, this setup uses 2 dials (one for setting which type of ingot you'd like to create (Standard Metal, Alloy or Super Alloy) and one for selecting specifically which type of ingot...532 downloadsupdated 7 y ago
- GIAC - Greenhouse Info, Automation and Controlby 3xpFeatures: 100% FULLY automated LArRE operation (scan, plant, get seeds, get harvest) Additional grow light automation based on util.time_of_day optional control for air conditioners, filtrations and gas mixing based on moles Supports up to 400 (technically 449) plant trays per rail system (you do...532 downloadsupdated 7 mo ago
- Satellite Tracking using the sine wave after updateby 76561198386747090Updated: V3.17.3 Satellite Tracking using the sine wave after update v1.6 Search the perforation with a sine curve and find the trader using waveform change for the signal found.​ 1. Operation: Operates when the power of the radar is turned on directly or through a logic switch. 2. If the automat...529 downloadsupdated 3 y ago
- Rocket controlby Art1985Controls rocket, rocket changes it's mining positions and comes back if fuel is not enough or storage is full. ​527 downloadsupdated 5 y ago
- TSO - Tank Status Overviewby 3xpFeatures Set up and view status for up to 12 gas/liquid analyzers at a glance You can change the name/label of each box in the settings to match the gas/liquid you want to track Shows temperature, pressure and liquid volume while the last 2 also have bars for display Top left shows status of pipe...527 downloadsupdated 7 mo ago
- Perfect Clockby MaybeWith well formated 24h! Original Script:525 downloadsupdated 6 y ago
- Steel Control for Auto Fill Furnaceby ImStillHereAintIThis will control smelting of Steel in your auto gas furnace. Needed: 1 IC, 1 Light d0 = Furnace d1 = Dial d2= Light for Steel d3= Inputmixer d4= Outputpump d5= N2 Pump​524 downloadsupdated 8 y ago
- Phenomenal Hardsuit Scriptby Wilhelm W. WalrusThis script will automatically control your hardsuit and helmet with options for manual overrides in case of a poisonous or hypoxic environment. Besides that, it can interface with its companion script to warn the player about storms or even remotely enable a tracking beacon. alias suit db alias...523 downloadsupdated 21 mo ago
- [F&S] Timer Relayby 123Description Turns on/off the specified devices at set intervals.​ Can turn on/off in batch mode. Requirements 1 IC Housing. 1 Integrated Circuit (IC10). IC ports description Port Device D0 Device to turn On/Off (Optional) Changeable values in IC code # Waiting for 3 seconds before the device bein...521 downloadsupdated 4 y ago
- Filter Automation - standaloneby Visitorek​Standalone Filter Automation script. It doesn't require any additional components (analyzers, housings, etc.), only an IC10 chip, placed inside the Filtration unit! How it works: - checks filter type (only in slot 0, the one on the right) - measures amount of selected type gas, using it's intern...519 downloadsupdated 13 mo ago
- Invar Control for Auto Fill Furnaceby ImStillHereAintIThis will control smelting of Invar in your auto gas furnace Needed: 1 IC chip, 1 light​ d0 = Furnace d1 = Dial d2= Light for Invar d3= Inputmixer d4= Outputpump d5= N2 Pump515 downloadsupdated 8 y ago
- Automated Night Lightby Oesche+++ English +++ The light switches on automatically when the sun sets. Change the setting at "Sunrise" to switch the light on earlier or later. Place the sensor on the floor with the connection facing north. d0 -> Daylight sensor If necessary, change the hash value to your specific light. +++ Deu...515 downloadsupdated 5 y ago
- LArRE (Hydroponics) Hydroponicsby Atrak*UPDATED* Default perennial list to include strawberries, blueberries, and watermelons. *NEW* Ability to designate stations for LArRE to ignore. *NEW* Control for up to two Linear Rail Doors. Automated harvesting and replanting of crops using LArRE (Hydroponics).​ Basic setup: LArRE (Hydroponics)...515 downloadsupdated 6 mo ago
- All Ores Light Control for Auto Fill Furnaceby ImStillHereAintIThis will turn on a light if the furnace is between 900 and 100000 kelvin in temperature, and the pressure is between 100 and 100000 kpa You will need 1 IC, 1 Light​ d0 = Furnace d1= Dial d2= AllOresLight (Light for all ores)513 downloadsupdated 8 y ago
- Furnace_v 3.0by Betelgeuse511 downloadsupdated 6 y ago
- 3 way Airlockby CowsAreEvilAllows for multiple doors in an airlock​ 2 or more, configure as needed. Note: All of the doors must be the same type or it will not work. ( configured as composite doors but it can be changed. ) All of the vents must be the same type or it will not work. ( configured as small vents but can be ch...510 downloadsupdated 19 mo ago
- IC Solar Trackingby gaming timePerfect solar tracking program​ Setup guide:509 downloadsupdated 4 y ago
- [F&S] Remote Buttons For Airlockby 123Description If you are using doors that do not have buttons (blastdoor, etc.), then you will need to remotely control the airlock. Requirements 1 IC Housing. 1 Integrated Circuit (IC10). 1 Kit (Logic Switch) type Button. (Optional) 1 Kit (Logic Transmitter). (Optional) IC ports description Port D...508 downloadsupdated 4 y ago
- Electrum Control for Auto Fill Furnaceby ImStillHereAintIThis will control smelting of Electrum in your auto gas furnace Needed: 1 IC chip, 1 light d0 = Furnace d1 = Dial d2= Light for electrum d3= Inputmixer d4= Outputpump d5= N2 Pump​506 downloadsupdated 8 y ago
- FSO - Filtration Status Overviewby 3xpFeatures Set up and view status for up to 12 filtration units (gas & liquid) at a glance You can change the name/label of each box in the settings to match the filtration gas/liquid you want to track which also acts as a easy device on/off label (light blue is on, dark red is off) Shows input tem...506 downloadsupdated 7 mo ago
- TTAC - Trade, Track and Contactby 3xpFeatures: Fully automated trader search, find and contact optional target/specific trader tracking Status overview with everything you need to know for the dish operations optional gas/liquid pump/regulator control including the Landingpad ATMO's Overview: Status display for the dish, tracking, c...504 downloadsupdated 7 mo ago
- Auto Fuel Mixer (Configurable)by gpedro178Auto Fuel Mixer by gpedro178 This is a very simple code that will let you set up a Mixer without having to worry about blowing a pipe. It's also very commented to allow users to learn from it and to modify it if they want to do other types of mixtures like a breathing mixture or a greenhouse mixt...498 downloadsupdated 6 y ago
- SDC- Satelite dish controlby HoschiTvHello dear community. In keeping with the latest update, I have renewed my satellite dish control. Now 3 Dials are no longer needed only 2. And the computer also switches on and off the satellite dish at the same time. My old controls are still in there, as I have no idea how I could have replace...497 downloadsupdated 7 y ago
- Constantan Control for Auto fill furnaceby ImStillHereAintIThis will control smelting of Constantan in your auto gas furnace Needed: 1 IC, 1 Light d0 = Furnace d1 = Dial d2= Light for Constantan d3= Inputmixer d4= Outputpump d5= N2 Pump​496 downloadsupdated 8 y ago
- Solder Control for Auto fill furnaceby ImStillHereAintIThis will control smelting of Solder in your auto gas furnace Needed: 1 IC, 1 Light d0 = Furnace d1 = Dial d2= Light for Solder d3= Inputmixer d4= Outputpump d5= N2 Pump​493 downloadsupdated 8 y ago
- Phenomal Hardsuit Companionby Wilhelm W. WalrusThis script is a companion to my hardsuit script. When hooked up to a logic transmitter that mirrors the suit, a weather station, and a beacon, the suit will be able to remotely enable the beacon, and it will recieve automatic weather updates. For more details: alias suitRadio d0 #logic transmitt...491 downloadsupdated 23 mo ago
- Flush Light for Furnance Auto Fill Flushby ImStillHereAintIThis chip will activate the flush light when flushing of the furnace 1 IC chip, 1 light​ d0= light d1= furnace IC chip488 downloadsupdated 8 y ago
- Battery Informationby PiFFdisplay of battery data on displays​482 downloadsupdated 6 y ago
- 1 Chip Furnace Managerby Lordm00m00Description This is a advanced furnace manager that only requires one IC10 Chip! This includes the recipes for all ingots from basic to super alloy as well, and hash display for the recipes. Instructions See the videos for more detailed guide on how to setup/tweak the code. The basic logic is tha...482 downloadsupdated 7 mo ago
- HarvieControllerby Elmo472 downloadsupdated 5 y ago
- Automation Arc Furnaceby Betelgeuse471 downloadsupdated 7 y ago
- RAC - Room Automation Controlby 3xpFeatures View room pressure, temperature and gas composition in a second Additional remote control options for filtrations, air conditioners and vents Auto mode for Filtration and Aircon - Turn off AC if in between +-2°C of setting || Turn of filtration until toxic gases are found Added a light v...468 downloadsupdated 7 mo ago
1.1k ic code mods, most downloaded first. Each one has its own page here with what it needs to run and where its author publishes it; the files themselves stay with the author and are never re-hosted on this site.

